You can wire Intellicon-(Flex8, 6+2) and Dflex adapters with the RS-422/485 option in various ways to communicate with RS-422/485 peripherals. Below is an example of a 4 wire cabling scheme as well as a 2 wire cabling scheme.
Intellicon Adapter RS-485 Peripheral
RS-422/485 Wiring Diagram( 2 Wire )
Intellicon Adapter RS-485 Peripheral
Note 1: The RTS and CTS connections are not necessary if you jumper the CTS selection ( J9 and J10 ) appropriately on the Intellicon-6+2.