Partial List of Dip Switch Settings for the NT960

Title: Partial List of Dip Switch Settings for the NT960
Keywords: Partial List of Dip Switch Settings for the NT960
Date: June 14 1997
KDB Number: kdb194
Distribution: External
Author: Support


Memory Address Switch Settings(SW2)
Memory Address
SW2 Switch Settings
1      2      3      4      5
* D0000 - D1FFF
on     on     on     off    on
D2000 - D3FFF
off    on     on     off    on
D8000 - D9FFF
on     on     off    off    on
DC000 - DDFFF
on     off    off    off    on
E0000 - E1FFF
on     on     on     on     off
E2000 - E3FFF
off    on     on     on     off
E8000 - E9FFF
on    on     off    on      off
EC000 - EDFFF
on     off    off    on     off
* - Default Setting

Port Address Switch Settings (SW1)
Port Address (Hex)
SW1 Switch Settings
1      2      3      4      5      6      7      8
280 - 283
on     on     on     on     on     off    on     off
288 - 28B
on     off    on     on     on     off    on     off
290 - 293
on     on     off    on     on     off    on     off
298 - 29B
on     off    off    on     on     off    on     off
* 300 - 303
on     on     on     on     on     on     off    off
304 - 307
off    on     on     on     on     on     off    off
308 - 30B
on     off    on     on     on     on     off    off
30C - 30F
off    off    on     on     on     on     off    off

* - Default Setting

For a complete list of Dip Switch settings, refer to the NT960 Manual